StarTech.com 32 Port Multi-user Cat5 Matrix IP KVM Switch Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Commutateurs KVM StarTech.com 32 Port Multi-user Cat5 Matrix IP KVM Switch. StarTech.com 32 Port Multi-user Cat5 Matrix IP KVM Switch Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Switch over IP

SV1653DXISV3253DXIEnterprise Class Multi-user Cat5 KVM Switch over IP

Page 2

Instruction Manual5CongurationSVxx53DXI offers four distinct methods for configuring the unit for your network. Which method will work best will depe

Page 3 - Table of Contents

Instruction Manual6You will be asked if you wish to change the default password. Select Yes or No as appropriate, then press Enter to continue. If no

Page 4

Instruction Manual7Using DHCPThis method requires that your network implement DHCP (Dynamic Host Configuration Protocol), usually on a server or networ

Page 5

Instruction Manual8please write this number down and keep it for future reference. Once you locate the MAC address of your unit in the DHCP log, you

Page 6 - Introduction

Instruction Manual9The following are the factory default values for the WAN port: IP Address: 192.168.1.123 Subnet Mask: 255.255.255.0 Defaul

Page 7 - Required Cables and Hardware

Instruction Manual10Connecting the Host Computer to the Unit *SV1653DXI rear panel shown Please note: It is strongly recommended that all systems sup

Page 8 - Installation

Instruction Manual11To disable mouse acceleration for the host computer operating system:Windows 98 From the Control Panel, click on 1. Mouse. From M

Page 9

Instruction Manual12Connect a USB keyboard and mouse device. (Please note that some 2. keyboards and mice may not work due to non-standard USB i

Page 10 - Conguration

Instruction Manual13Using SVxx53DXI’s web interface requires a browser, with cookies and JavaScript enabled. To start the Java VNC client, login to th

Page 11 - Instruction Manual

Instruction Manual14display a warning about an invalid security certificate. This does not af-fect the security of your data in any way.Whenever you a

Page 12 - Using DHCP

FCC Compliance StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may

Page 13

Instruction Manual15After the initial login screen, the Home screen will appear, offering a Screen Thumbnail view of the controlled computer, as well

Page 14

Instruction Manual16User PreferencesThe User Preferences screen offers several configuration options, per-taining to the functionality of SVxx53DXI on

Page 15

Instruction Manual17LogoutClicking on Logout logs you completely out of the SVxx53DXI interface. You will have to login again to gain access to the w

Page 16

Instruction Manual18When the host computer next looks at the drive, it will notice the changes. You can read files from the virtual disk at any time, a

Page 17 - Using the Web Interface

Instruction Manual19SVxx53DXI is able to read most MS-DOS/Windows formatted disks and presents the files via the Web interface. However, disk emulatio

Page 18 - The Login Screen

Instruction Manual20Booting from USB Disk:If the host computer’s BIOS supports USB boot devices, it is possible to boot from the emulated CD-ROM or flo

Page 19 - Web Interface Introduction

Instruction Manual21Admin FunctionsThe Admin functions allow you to access all of the features you will need to perform an initial configuration of the

Page 20

Instruction Manual22When disabled, the LAN port will use the values assigned to it in the IP Addresses and Routing section described below. IP Address

Page 21

Instruction Manual23You may connect both the WAN and LAN ports to the same logical network through redundant Ethernet switches. If one switch fails, t

Page 22

Instruction Manual24Click to select the None/View/Control radio button as appropriate. User ListSelect which user to change, by clicking on their name

Page 23

Instruction ManualiInstruction ManualTable of ContentsIntroduction ...

Page 24

Instruction Manual25 Other identification detailsThese values are for information purposes only. They are visible from the VNC client and via SNMP (if

Page 25

Instruction Manual26DescriptionA user-defined description for the controlled machine. SecurityThis menu allows you to configure a number of settings, in

Page 26 - Admin Functions

Instruction Manual27SNMPThe SNMP menu allows you to configure the SVxx53DXI so it can be recognized and managed using industry-standard Simple Network

Page 27

Instruction Manual28in the form name.local is given at the RADIUS prompt, the system will use name, check the password locally and skip RADIUS authent

Page 28

Instruction Manual29Auto Self UpgradeClicking the Upgrade to latest button will automatically download and install necessary revisions. To download up

Page 29

Instruction Manual30Look for a unique code, such as: 4-C80C-B960-1-0. If you provide this code to the technical support department, they can provide y

Page 30

Instruction Manual31Port NumbersPort Numbers provides a table allowing you to change TCP port values for services available on the SVxx53DXI. By defau

Page 31

Instruction Manual32Help MenuProvides an FAQ (Frequently Asked Questions) listing to assist you with the features and operation of the SVxx53DXI. Site

Page 32

Instruction Manual33Native VNC ClientThis system implements the VNC protocol, so any off-the-shelf VNC client can be used. There are several differen

Page 33

Instruction Manual34 any number (1025...65535). It is the port number used on your client machine to connect your local SSH instance with the VNC

Page 34

Instruction ManualiiNetwork Config ...21User Accounts ...

Page 35 - Info Functions

Instruction Manual35Resync: Re-aligns the remote and local mouse points so they are on top of each other. Redraw: Redraws the entire screen con-tents;

Page 36

Instruction Manual36By hovering the mouse over any entry, you can see details pertaining to that entry.Select one of the listed systems by clicking on

Page 37 - The VNC Interface

Instruction Manual37Main MenuTo access the main menu, quickly press the F7 key twice quickly. You must press the key twice within one second. If you p

Page 38

Instruction Manual38IdentificationFixed text label that is defined by the user in the Web interface. This does not affect the operation of the system an

Page 39

Instruction Manual39to take control away from another user. Only one user may control the keyboard and mouse at any time. All users see the same pictu

Page 40

Instruction Manual40VirtKeys MenuClicking any button in the top half of the window simulates pressing and releasing the indicated key. In the bottom a

Page 41

Instruction Manual41Video Tuning MenuUse the Auto Everything button to automatically fine-tune all three adjust-ments. If the test pattern for Color Of

Page 42

Instruction Manual42Color OffsetColor Offset is a fine tuning adjustment that requires the use of a test pat-tern. There is a copy of the test pattern

Page 43

Instruction Manual43Flatness FilterTo improve compression ratios, the SVxx53DXI will group adjacent pixels that are nearly the same colour and treat t

Page 44

Instruction Manual44 much data as your network connection and VNC client allow.Network latency, which is the total time it takes for a packet to get

Page 45

Instruction ManualiiiModem Troubleshooting Guide ...55About Security Certificate Warnings ...

Page 46

Instruction Manual45the parameter to the middle value. The text of the middle button also indi-cates which parameter is being controlled. Note that in

Page 47

Instruction Manual46Disk Control MenuStatus: Shows the current disk type. This can be changed through the web interface.Access: Shows the number of co

Page 48

Instruction Manual47Accessing KVM Features OSD OperationsStart the OSD (On-Screen Display) by pressing the left <CTRL> or <ScrLk> key twic

Page 49

Instruction Manual48OSD Function Keys Please Note: Channel names can only be changed through the web interface. Changing Your Configuration After the

Page 50

Instruction Manual49Using the Modem feature NOTE: Requires an RJ45 to DB9 adapter. Please see StarTech.com part number(s): GC98FF (DB9 Female to RJ

Page 51 - Disk Control Menu

Instruction Manual50Connecting a Modem The SVxx53DXI will work with virtually any Hayes-compatible modem that recognizes the standard AT command set.

Page 52 - Accessing KVM Features

Instruction Manual51is connected. It requires the use of a null modem serial cable. Place the modem near the SVxx53DXI and an available telephone 1.

Page 53

Instruction Manual52and configures the following connection properties: answer incoming calls on the first ring, enable hardware flow control, and lock t

Page 54 - Using the Modem feature

Instruction Manual53The 4. New Connection Wizard window will open. Click Next. Select 5. Connect to the Internet, then click Next. Select 6. Set up

Page 55

Instruction Manual54The following TCP/IP port numbers are assigned for a PPP connection, regardless of the settings configured in the Web interface for

Page 56

Instruction Manual1IntroductionThank you for purchasing a StarTech.com Enterprise Class KVM. Using the Internet or your TCP/IP enabled network, you c

Page 57

Instruction Manual55Modem Troubleshooting Guide The following messages will appear in the system log on the Status screen in the Web interface and may

Page 58

Instruction Manual56essential details about a site that must match the information supplied to your Web browser. Why do I receive a warning when acce

Page 59

Instruction Manual57When prompted, choose 2. Open. A Window will appear that offers information about the certificate. Click 3. Install Certificate

Page 60

Instruction Manual58Built-in Terminal EmulationThe built in Terminal Emulator is an ANSI terminal that allows local users (Directly connected or via t

Page 61

Instruction Manual59How to create a New Connection (Using the Wizard)Use the arrow keys or underlined letter to select “Create new 1. connection (u

Page 62

Instruction Manual60If you are choosing “Direct”, use the screens that follow to choose the 3. appropriate setting for your serially attached devic

Page 63 - Built-in Terminal Emulation

Instruction Manual61If you are using SSH you will be asked to provide the remote 5. username. Next you will be asked to declare any alternative SS

Page 64

Instruction Manual62Once you have created your new connection you will see it listed above the other commands in the main menu. You may activate this

Page 65

Instruction Manual63Troubleshooting Forgotten master passwordYou can reset the master password using the serial interface on the unit. Use the S comma

Page 66

Instruction Manual64running SSH. You should answer yes so that your SSH client saves the public key of this host and doesn’t re-issue this warning. Ce

Page 67

Instruction Manual2Required Cables and Hardware Depending on your needs, you may need one or more of the following cables. Please note that the corre

Page 68 - Troubleshooting

Instruction Manual65Serial Interface PinoutRJ45 DB9 (male) Signal1 6 DSR (input)2 1 DCD (input)3 4 DTR (output)4 5 GND 5 2 RxD (input)6 3 TxD (output)

Page 69

Instruction Manual66Technical SpecicationsMaximum Recommended Resolution1280 x 1024@ 60HzMaximum Supported Resolution1600 x 1200 @ 60 HzHost Connecto

Page 70 - Serial Interface Pinout

Instruction Manual67Storage Temperature-40°C to 65°C ( -40°F to 158°F)Operation Temperature0°C to 40°C (32°F to 104°F)Humidity80% rh, ncDimensions310

Page 71 - Technical Specications

Instruction Manual68Technical SupportStarTech.com’s lifetime technical support is an integral part of our commit-ment to provide industry-leading solu

Page 72

StarTech.com has been making “hard-to-find easy” since 1985, providing high quality solutions to a diverse IT and A/V customer base that spans m

Page 73 - Warranty Information

Instruction Manual3Installation*SV1653DXI front panel *SV1653DXI rear panel To connect the KVM Remote Control Unit to the Host Computer and Netw

Page 74

Instruction Manual4

Commentaires sur ces manuels

Pas de commentaire